Home| Air Preparation | Fittings | Hose | About Us| Contact Us
LINE 042 1/4"
BACK
The new line 042 is characterized by a high versatility thanks to the double assembling system.
Infact, the usual UNIT ASSEMBLING KIT (see picture 1) is utilized for assembling standard combined units such as FR+L, V3+FR+L, F+R+L, F+L e F+MF. Besides being really practical and functional, this unit assembling kit reduces to the minimum the assembled unit overall dimensions.
For assembling particularly complex groups, the BATTERY ASSEMBLING KIT (see picture 2) is utilized. This battery assembling kit, which is preassembled on single standard products, allows for innumerable combinations to meet the
most demanding application requirements.
Download LINE 042 PDF
042 Regulator
042 Filter
042 Lubricator
042 Filter Regulator
042 3 Way on-off valve
042 Shut-off valve
042 Slow start valve
042 Modular Line Overview
Back to the top of page
042 Regulator
* Sensitive high performance model with rolling diaphragm; high stability with low
load losses and big flow rate.
* Can be wall mounted using the relative holes or a bracket.
* Lockable safety knob.
* Built-in overpressure relieving function.
* Pressure ranges:
0-4 Bar, 0-8 Bar (standard), 0-12.5 Bar
0-0.4 MPa, 0-0.8 MPa (standard), 0-1.25 MPa
* Maximum inlet pressure: 16.0 Bar (1.60 MPa).
* Temperature range: 5-50°C (41-122°F).
* Gauge connection: G1/8”.
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=6.3 Bar - Dp=1 Bar): 850 Nl/min.
* Weight: 0.125 Kg.

Back to the top of page
042 Filter
* High level of condensate separation.
* Low pressure drop.
* Can be wall mounted using the relative holes.
* Filtering degree: 5 micron and 20 micron (standard).
* Manual and semiautomatic condensate drainage in the integrated (S) or float
type automatic version (A).
* Bowl available in two configurations: transparent toughened polyamide or with
outer bowl guard.
* Collected quantity of condensate: 22 cc.
* Maximum operating pressure: 16.0 Bar (1.60 MPa).
* Temperature range: 5-50°C (41-22°F).
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=10 Bar - Dp=1 Bar): 1250 Nl/min.
* Weight: 0.095 Kg.

042 Coalescent Oil Vapour Removal Filter

Essential in circuits where oil is not permitted.
* Coalescent cartridge made in microfiber, allows an high filtration efficiency of
99,99% on 0.1 micron particles.
* Can be wall mounted using the relative holes.
* Manual and semiautomatic condensate drainage in the integrated (S) or float
type automatic version (A).
* Bowl available in two configurations: transparent toughened
poliamide or with outer bowl guard.
* It is advisable to install a filter with 5 micron element, to consent long-lasting
of coalescent cartridge.
* Maximum operating pressure: 16.0 Bar (1.60 MPa).
* Temperature range: 5-50°C (41-22°F).
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=6.3 Bar - Dp=1 Bar): 195 Nl/min.
* Weight: 0.095 Kg.
Back to the top of page
042 Lubricator
Proportional oil mist type.
* Constantly steady delivery.
* Suction ensured even with low flow rates.
* Sensitive lubricant flow adjustment.
* 360° drip display.
* Oil fill plug.
* Can be wall mounted using the relative holes.
* Bowl available in two configurations: transparent toughened
polyamide or with outer bowl guard.
* Bowl capacity: 42 cc.
* Recommended oil viscosity ISO VG32.
* Maximum operating pressure: 16.0 Bar (1.60 MPa).
* Temperature range: 5-50°C (41-22°F).
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=10 Bar - Dp=1 Bar): 2060 Nl/min.
* Weight: 0.095 Kg.

042 Automatic Filling Lubricator

Essential when the oil must be quickly and safety loaded without interrupting the
normal operation of the system.
* Filling is achieved by keeping the button at the base of the lubricator casing
depressed. This provokes a vacuum inside the bowl enabling the oil to be
intaken.
* The flow will only interrupt when the button is released.
* The oil level must be visually inspected.
* Minimum activation pressure: 3 Bar (0,3 MPa).
* Other functional features as standard model.
* Reference flow rate (P=10 Bar - Dp=1 Bar): 2060 Nl/min.
* Weight: 0.140 Kg.
Back to the top of page
042 Filter Regulator
* Sensitive high performance model with rolling diaphragm; high stability with low
load losses and big flow rate.
* Can be wall mounted using the relative holes or on brackets.
* Lockable safety knob.
* Built-in overpressure relieving function.
* High level of condensate separation.
* Pressure ranges:
0-4 Bar, 0-8 Bar (standard), 0-12.5 Bar
0-0.4 MPa, 0-0.8 MPa (standard), 0-1.25 MPa
* Filtering degree: 5 micron and 20 micron (standard).
* Manual and semiautomatic condensate drainage in the integrated (SS) or float
type automatic version (SA).
* Bowl available in two configurations: transparent toughened polyamide or with
outer bowl guard.
* Collected quantity of condensate 22 cc.
* Maximum inlet pressure: 16.0 Bar (1.60 MPa).
* Temperature range: 5-50°C (41-122°F).
* Gauge connection: G1/8”.
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=6.3 Bar - Dp=1 Bar): 850 Nl/min.
* Weight: 0.160 Kg.
Back to the top of page
Manual 3 way shut off valve
Used to shut off the air supply while relieving the downstream circuit.
* The block device is particularly useful during maintenance operations. It prevents
the system from being accidentally or wrongly pressurized.
* It can be wall mounted using the relative holes.
* Discharge connection: G 1/8”.
* Maximum inlet pressure: 16.0 Bar (1.60 MPa).
* Temperature range: 5-50°C (41-122°F).
* The device is equipped with 1 lock.
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=10 Bar - Dp=1 Bar): 1570 Nl/min.
* Weight: 0.155Kg.
Back to the top of page
Remote controlled shut off valve
Used to shut off the air supply while relieving the downstream circuit.
* The block device is particularly useful during maintenance operations. It prevents
the system from being accidentally or wrongly pressurized.
* It can be wall mounted using the relative holes.
* Discharge connection: G 1/8”.
* Maximum inlet pressure: 10.0 Bar (1.00 MPa).
* Temperature range: 5-50°C (41-122°F).
* The device is equipped with 1 lock.
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=10 Bar - Dp=1 Bar): 1570 Nl/min.
* Weight: 0.155Kg.
Back to the top of page
Slow start valve
Gradually pressurizes the system until reaching the set operating pressure value.
* Before delivering the maximum available pressure, the air is allowed to slowly
flow around the downstream circuit until about 60% of the pressure is reached
upstream.
* Use the built-in flow governor to establish the pressurizing time.
* It can be wall mounted using the relative holes.
* Minimum pressure admitted: 3 Bar (0,3 MPa).
* Maximum inlet pressure: 10.0 Bar (1.00 MPa).
* Temperature range: 5-50°C (41-122°F).
* Max. torque inserts G1/4” IN-OUT: 25 N·m.
* Reference flow rate (P=10 Bar - Dp=1 Bar): 1570 Nl/min.
* Weight: 0.136 Kg.
Back to the top of page
042 Modular Line Overview
Back to the top of page